Model | Alpha | Beta | Gamma | Neutron | Application | Detector Type | Characteristics |
---|---|---|---|---|---|---|---|
42-5 | x | Survey | Scintillation, LiI | Accompanied with a cart holding 2, 3, 5, 8, 10, and 12 in. dia. polyethylene spheres | |||
42-30H | x | Survey | He3 Proportional | 10 in. dia. polyethylene sphere | |||
42-31H | x | Survey | He3 Proportional | 9 in. dia. polyethylene sphere | |||
42-38 | x | Wide Energy Survey | He3 Proportional | 9 in. dia. polyethylene cylinder | |||
42-41L | x | Survey & Dose | Scintillation, Proton Recoil | PRESCILA | |||
43-1 | x | Alpha Survey | Scintillation, ZnS(Ag) | 83 cm2 active, 75 cm2 open | |||
43-1-1 | x | x | Alpha-Beta Survey | Scintillation, ZnS(Ag) + Plastic | 83 cm2 active, 75 cm2 open | ||
43-2 | x | Alpha Survey | Scintillation, ZnS(Ag) | 9.7 cm2 active and open | |||
43-2-2 | x | x | Alpha-Beta Survey | Scintillation, ZnS(Ag) + Plastic | 9.7 cm2 active and open | ||
43-5 | x | Alpha Survey | Scintillation, ZnS(Ag) | 76 cm2 active, 50 cm2 open | |||
43-9 | x | Sample Counting | Scintillation, ZnS(Ag) | Sample size 2.5 cm (1 in.) dia. | |||
43-10 | x | Sample Counting | Scintillation, ZnS(Ag) | Sample size 5.1 cm (2 in.) dia., Windowless | |||
43-10-1 | x | x | Alpha-Beta Sample Counting | Scintillation, ZnS(Ag) + Plastic | Sample size 5.1 cm (2 in.) dia. | ||
43-10-10 | x | x | Alpha-Beta Sample Counting | Scintillation, ZnS(Ag) + Plastic | Sample size 5.1 cm (2 in.) dia., iCam filter adapter | ||
43-37-1 | x | x | Alpha-Beta Survey | Gas Proportional | 821 cm2 active, 609 cm2 open | ||
43-44 | x | Alpha Survey | Air Proportional | 76 cm2 active, 50 cm2 open | |||
43-44-1 | x | Alpha Survey | Air Proportional | 154 cm2 active, 100 cm2 open | |||
43-65 | x | Alpha Survey | Scintillation, ZnS(Ag) | 63 cm2 active, 50 cm2 open | |||
43-65-1 | x | Beta Survey | Scintillation, Plastic | 63 cm2 active, 50 cm2 open | |||
43-65-2 | x | x | Alpha-Beta Survey | Scintillation, ZnS(Ag) + Plastic | 63 cm2 active, 50 cm2 open | ||
43-68 | x | x | Alpha-Beta Survey | Gas Proportional | 126 cm2 active, 100 cm2 open | ||
43-78 | x | Large Sample Counting, Alpha | Scintillation, ZnS(Ag) | Sample size 12.7 cm (5 in.) dia., Windowless | |||
43-78-1 | x | Large Sample Counting, Beta | Scintillation + Plastic | Sample size 12.7 cm (5 in.) dia., Windowless | |||
43-78-2 | x | x | Large Sample Counting, Alpha-Beta | Scintillation, ZnS(Ag) + Plastic | Sample size 7.6 cm (3 in.) dia. | ||
43-89 | x | x | Alpha-Beta Survey | Scintillation, ZnS(Ag) + Plastic | 125 cm2 active, 100 cm2 open | ||
43-90 | x | Alpha Survey | Scintillation, ZnS(Ag) | 125 cm2 active, 100 cm2 open | |||
43-92 | x | Alpha Survey | Scintillation, ZnS(Ag) | 100 cm2 active, 88 cm2 open | |||
43-93 | x | x | Alpha-Beta Survey | Scintillation, ZnS(Ag) + Plastic | 100 cm2 active, 88 cm2 open | ||
43-135-1 | x | x | Alpha-Beta Survey | Gas Proportional | Large Area, Low Background | ||
43-136 | x | Alpha Survey | Scintillation, ZnS(Ag) | 65.3 cm2 active | |||
43-143-1 | x | x | Alpha-Beta Survey | Gas Proportional | 100 cm2 active, 70 cm2 open | ||
43-147 | x | x | Alpha-Beta Survey | Scintillation, ZnS(Ag) + Plastic | 200 cm2 active, 176 cm2 open | ||
44-1 | x | Survey, Sample Counting | Scintillation, Plastic | 9.7 cm2 active and open | |||
44-2 | x | Low-level, wide energy gamma detection | Scintillation, NaI(Tl) | 2.5 x 2.5 cm (1 x 1 in.) scintillator | |||
44-3 | x | 125I & Low-Energy Gamma Survey | Scintillation, NaI(Tl) | 5 cm2 active & open | |||
44-6 | x | x | Survey | GM | Sliding beta shield | ||
44-7 | x | x | x | Survey & Sample Counting | GM, End Window | 6 cm2 active, 5 cm2 open | |
44-9 | x | x | x | Survey & Sample Counting | GM, Pancake | 15.5 cm2 active, 12.3 cm2 open | |
44-9-18 | x | x | x | Survey & Sample Counting | GM, Pancake | 15.5 cm2 active, 12.3 cm2 open, telescoping handle | |
44-10 | x | Low-level, wide energy gamma detection | Scintillation, NaI(Tl) | 5.1 x 5.1 cm (2 x 2 in.) scintillator | |||
44-11 | x | Survey, Sample Counting | Scintillation, NaI(Tl) | 5.1 x 5.1 cm (2 x 2 in.) scintillator | |||
44-17 | x | 125I & Low-Energy Gamma Survey | Scintillation, NaI(Tl) | 17.8 cm2 active & open | |||
44-20 | x | Survey, Sample Counting | Scintillation, NaI(Tl) | 7.6 x 7.6 cm (3 x 3 in.) scintillator | |||
44-21 | x | x | Survey, Sample Counting | Scintillation, Plastic | 5.1 cm2 active & open | ||
44-25 | x | x | x | Hand Contamination Monitoring | GM, Pancake (2 ea.) | 31 cm2 active, 18 cm2 open | |
44-26 | x | x | x | Foot Contamination Monitoring | GM, Pancake (3 ea.) | 46 cm2 active, 27 cm2 open | |
44-38 | x | x | Survey | GM | Sliding beta shield | ||
44-40 | x | x | x | Survey & Sample Counting | GM, Pancake | 15.5 cm2 active, 12.3 cm2 open, shielded | |
44-40-2 | x | x | x | Survey | GM | 15.5 cm2 active, 12.3 cm2 open, shielded | |
44-62 | x | Low-level, wide energy gamma detection | Scintillation, NaI(Tl) | 1.3 x 2.5 cm (0.50 x 01 in.) scintillator | |||
44-88 | x | x | x | Survey & Sample Counting | GM, Pancake | 15.5 cm2 active, 12.3 cm2 open | |
44-89 | x | x | x | Survey | GM, Pancake (4 ea.) | 62 cm2 active, 50 cm2 open | |
44-92 | x | x | Survey | Gas Proportional | Xenon sealed, 169 cm2 active, 140 cm2 open | ||
44-94 | x | x | x | Survey | GM, Pancake (4 ea.) | 62 cm2 active, 50 cm2 open | |
44-98 | x | x | Survey, Sample Counting | Scintillation, BGO | 5 cm2 active & open | ||
44-110 | x | Survey, Tritium Contamination | Gas Proportional | P-10 gas flow, 126 cm2 active, 100 cm2 open, windowless | |||
44-110-4 | x | x | Sample Counting, Tritium | Gas Proportional | Sample size 5.1 cm (2 in.) dia. | ||
44-116 | x | Beta Survey | Scintillation, Plastic | 125 cm2 active, 100 cm2 open | |||
44-132 | x | µR Gamma Survey | Scintillation, Plastic | 14.6 x 2.5 cm (5.75 x 1 in.) scintillator | |||
44-142 | x | Survey | Scintillation, Plastic | 100 cm2 active, 88 cm2 open | |||
44-150-1 | x | Survey | GM, Energy Compensated | Range: 0.1 to 50 mR/hr without DTC | |||
44-150-3 | x | Survey | GM, Energy Compensated | Range: 0.01 to 8 mR/hr without DTC | |||
44-159-1 | x | Survey | Scintillation, CsI | 18 x 18 mm (0.7 x 0.7 in.) scintillator | |||
44-172 | x | Low-Energy Gamma Survey | YSO | 5 cm2 active & open | |||
44-183 | x | Gamma Survey | GM, Energy Compensated | Shielded, Range: 1 mR/hr to 2 R/hr without DTC | |||
44-213 | x | Low-Energy Gamma Survey | Scintillation, CsI | 127 cm2 active & open | |||
44-215 | x | Beta Survey | Scintillation, Plastic | 20 cm2 active, 16.7 cm2 open | |||
133-Series | x | Survey, dose rate | GM, Energy Compensated | Range: between 0.1 mR/h to 30 R/h without DTC | |||
120 | x | x | x | Alpha-Beta-Gamma Sample Counting | Gas Proportional | Sample size 5.1 cm (2 in.) dia. | |
180-8 | x | x | x | Sample Counting | GM, End Window | 6 cm2 active, 5 cm2 open, shielding | |
203 | x | Assay Sample Counting | Scintillation, NaI(Tl) | 1.5 in. thick lead shielding | |||
243 | x | Assay Sample Counting | Scintillation, NaI(Tl) | 0.5 in. thick lead shielding |