Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Health Physics Medical Physics Metal Recycling Monitoring SystemsEmergency Response

All Products

Portable Survey Meters

  • Friskers
  • General Purpose - Digital
  • General Purpose - Analog
  • Computerized
  • Data Loggers
  • Specialized Meters
  • Geiger Counters
  • Intrinsically Safe
  • Ion Chambers
  • Isotope Identifiers
  • microR / microSv Meters
  • Extended Reach microR / microSv Meters
  • Neutron Meters
  • Pocket-Size Meters
  • Scaler-Ratemeters
  • Stretch Scopes

Personal Radiation Meters

No subcategories

Benchtop Meters

No subcategories

Scalers / Counters

No subcategories

Pulsers

No subcategories

Detectors

  • Alpha
  • Alpha-Beta
  • Alpha-Beta-Gamma
  • Beta
  • Gamma GM
  • Gamma Scintillator
  • Low-Energy Gamma Scintillator
  • Neutron
  • Waterproof Detectors
  • Pipe Detectors
  • Sample Counter Heads
  • Sample Holders

Monitoring Systems

  • Area Monitor Controllers
  • Area Monitoring Systems
  • Portal Monitors
  • Monitoring Systems
  • Contamination Monitors
  • Article Monitors
  • Air Monitors
  • Hand & Foot Monitors
  • Body Monitors
  • Vehicle Monitors
  • Scrap Monitoring Systems
  • Laundry Monitors

Ground/Floor Surveying

No subcategories

Sample Counting

  • Sample Counting Systems
  • Scalers / Counters
  • Sample Counter Heads
  • Protean Instrument Alpha-Beta Counting Systems

Tritium Monitoring

No subcategories

NORM Kits

No subcategories

Dosimetry

  • Dosimeters
  • Dosimeter Accessories

Accessories

  • Detector Accessories
  • Handles & Straps
  • Audio
  • Cables, Connectors & Signal Converters
  • Check Sources
  • Instrument Cases

Medical Physics

  • Radiation Safety QA
  • Imaging QA Test Tools
  • CT / MRI QA
  • Mammography QA
  • Ultrasound QA
  • Nuclear Medicine QA & Safety

Emergency Response Kits

  • General Response Kits
  • Medical Response Kits
  • Decontamination Kits

Need Help?

Unsure about which instrument is best for your application?

Find your region's Ludlum representative or dealer.

  • US Contacts
  • International Contacts

OR

Contact Ludlum Sales:

(800) 622-0828 (USA Toll Free)

(325) 235-5494

Newsletter

Subscribe to our customer newsletter! Stay informed about Ludlum products and services, and get helpful support tips.

Please enable the javascript to submit this form

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

m3030e_545x700

Model 3030E

Alpha-Beta Scaler

Part Number: 48-3448

Features

  • Dual Channel Scaler with Independent Readouts
  • Connects to External Sample Head/Detector
  • CPM & DPM Modes
  • Background Subtraction
  • Alpha/Beta Alarms
  • QC Check
  • 8 Hour Battery Operation
  • Real Time Clock
  • RS-232 Interface
  • Includes PC Software

The Model 3030E is a dual channel, scaler-type, sample counter electronics package that will accommodate many detector inputs from external sample head/detectors. This design represents a significant improvement over older analog type scalers by providing greater utility and functionality.

The system incorporates independent backlit LCD readouts to support discriminated alpha and beta sample counting. The system features background subtraction, crosstalk correction, separate alpha/beta alarms, cpm/dpm operating modes, and a pre-scripted QC function with an automatic reminder timer.

The instrument supports both 110 and 220 Vac operation and includes a trickle-charged gel-cell battery for portable offsite use up to eight hours. A wide-range, high-voltage power supply supports virtually any detector.

Status indicators located along the front panel inform the operator when another QC check is required, if the detector is nonfunctional, if it is operating in DPM or CPM mode, and if either an alpha or beta alarm setpoint has been exceeded. The count time is selected via a front panel rotary switch that enables count times ranging from 0.1 to 60 minutes or some other prescribed value as set up via a link to a PC. Other controls include a start count button, audio volume rotary adjustment, and instrument on/off switch.

An RS-232 output from the rear panel supports connection to either a printer or PC. Included in the price is PC control software, which is a Windows application that supports setup of the system, as well as collecting and logging all count results from the 3030E.

 

  • Specifications
  • Options
  • Documents
  • Software
  • Specifications
  • Options
  • Documents
  • Software

Specifications

Indicated Use Simultaneous alpha-beta sample counting
Scalers Two ea. six-digit LCD displays with back lights providing a range of 0 to 999999 counts
Scaler Linearity Reading within 2% of true value
Count Timer Settings 0.1, 0.5, 1, 2, 5, 10, and 60 minutes. PC position facilitates other user-defined values set by software program.
Audio Built-in unimorph type speaker with volume control to provide a dual tone click-per-event audio
Status Indicators
  • Backlit indicators for daily QC check needed (QC)
  • Scintillation detector is in overload condition (OL)
  • Counting in cpm or dpm mode (CPM/DPM)
  • Count has exceeded alpha alarm set point (∝AL)
  • Count has exceeded beta alarm set point (βAL)
Detector Connector "C" type
High Voltage Adjustable from 200 to 2500 volts
Thresholds Beta: -4 mV
Alpha: -120 mV
Beta Window: -50 mV
Alpha Window: -120 mV
Data-Output 9-pin RS-232 port for connection to PC for data download and adjustment of setup parameters. A one meter RS-232 to USB adapter cable is included. PC interface software is available for download here.
Power 250 W at 95 to 250 Vac, 50-60 Hz single phase
Internal 12 Vdc, 1.2 A/hr, trickle-charged battery provides power for up to eight hours

Options

OptionDescriptionPart Number
alpha_beta_sampl_4aeaf499dc7ca
Model 43-10-1
Alpha-Beta sample counter head. Sample drawer has holder for 2.5 cm (1 in.) and 5.1 cm (2 in.) dia. samples. 47-1305
m43-10-10_2119781496
Model 43-10-10
Alpha-Beta sample counter head. Sample drawer has holder for 2.5 cm (1 in.) and 5.1 cm (2 in.) dia. samples, as well as a cutout for iCam filter cards. 47-4114
m43-78-2_a
Model 43-78-2
Alpha-Beta sample counter head. Can hold samples up to 7.6 x 0.46 cm (3 x 0.18 in.) [D x L] in size. 47-2620
model_4167-386
Printer
Printer with power adapter, printer paper, cable, and driver software CD. 4167-386

Documents

  • Data Sheet
  • Product Manual
  • CE Certificate

Software

PC interface software and the driver needed to use the RS-232 to USB adapter cable are available for download on the Software & Firmware Downloads page.


Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.