Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Health Physics Medical Physics Metal Recycling Monitoring SystemsEmergency Response

All Products

Portable Survey Meters

  • Friskers
  • General Purpose - Digital
  • General Purpose - Analog
  • Computerized
  • Data Loggers
  • Specialized Meters
  • Geiger Counters
  • Intrinsically Safe
  • Ion Chambers
  • Isotope Identifiers
  • microR / microSv Meters
  • Extended Reach microR / microSv Meters
  • Neutron Meters
  • Pocket-Size Meters
  • Scaler-Ratemeters
  • Stretch Scopes

Personal Radiation Meters

No subcategories

Benchtop Meters

No subcategories

Scalers / Counters

No subcategories

Pulsers

No subcategories

Detectors

  • Alpha
  • Alpha-Beta
  • Alpha-Beta-Gamma
  • Beta
  • Gamma GM
  • Gamma Scintillator
  • Low-Energy Gamma Scintillator
  • Neutron
  • Waterproof Detectors
  • Pipe Detectors
  • Sample Counter Heads
  • Sample Holders

Monitoring Systems

  • Area Monitor Controllers
  • Area Monitoring Systems
  • Portal Monitors
  • Monitoring Systems
  • Contamination Monitors
  • Article Monitors
  • Air Monitors
  • Hand & Foot Monitors
  • Body Monitors
  • Vehicle Monitors
  • Scrap Monitoring Systems
  • Laundry Monitors

Ground/Floor Surveying

No subcategories

Sample Counting

  • Sample Counting Systems
  • Scalers / Counters
  • Sample Counter Heads
  • Protean Instrument Alpha-Beta Counting Systems

Tritium Monitoring

No subcategories

NORM Kits

No subcategories

Dosimetry

  • Dosimeters
  • Dosimeter Accessories

Accessories

  • Detector Accessories
  • Handles & Straps
  • Audio
  • Cables, Connectors & Signal Converters
  • Check Sources
  • Instrument Cases

Medical Physics

  • Radiation Safety QA
  • Imaging QA Test Tools
  • CT / MRI QA
  • Mammography QA
  • Ultrasound QA
  • Nuclear Medicine QA & Safety

Emergency Response Kits

  • General Response Kits
  • Medical Response Kits
  • Decontamination Kits

Need Help?

Unsure about which instrument is best for your application?

Find your region's Ludlum representative or dealer.

  • US Contacts
  • International Contacts

OR

Contact Ludlum Sales:

(800) 622-0828 (USA Toll Free)

(325) 235-5494

Newsletter

Subscribe to our customer newsletter! Stay informed about Ludlum products and services, and get helpful support tips.

Please enable the javascript to submit this form

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

m334a
m334am334a-side

Model 334A

Alpha Air Monitor

Part Number: 48-3859

Features

  • Easy Setup and Use
  • Integrated LCD and Touch Screen Display
  • English or SI Units of Measurement
  • Acute and Chronic Dose Modes
  • Significantly Reduced False Alarms  Using Peak Shape Fitting Capability
  • 8-Hour Battery Life
  • Radon Mode Option

The Model 334A is a compact, lightweight, and portable alpha air monitor designed to function both as a workplace monitor and a Continuous Air Monitor (CAM) for measurements in emergency response situations. Its functionality is enhanced by its splash- and dust-proof enclosure with splash-proof electronics.

Spectral analysis is conducted via a 1024-channel analyzer that feeds data to the embedded processor. Factory configuration provides either special nuclear materials (SNM) or radon progeny measurements of potential alpha energy concentration (PAEC).

Measurements may be taken in both fast-responding (Acute) or high-sensitivity (Chronic) assessments, and report in English or SI units. The Model 334A stores acquired data in comma-separated-variable (.csv) format that is recognized by most spreadsheet and database software. Data may be saved in the instrument’s internal memory, or alternately may be written to an SD card for later retrieval and review.

Independent determination of nuclide peaks means they are impervious to radon equilibrium changes, thereby contributing to low probabilities of error and false alarms. Precise fitting of the 218Po tail results in excellent sensitivity.

This Model 334A features an integrated LCD and touch screen that displays information on instrument status and readings during operation. The estimated dose of the isotope(s) of interest and instrument status is displayed at all times. A window below may be switched from showing historical readings and battery status, or displaying the current spectrum.

Factory-configurable Radon Mode allows the instrument to monitor potential-alpha-energy-concentration (PAEC) of radon progeny.

 

  • Specifications
  • Options
  • Documents
  • Specifications
  • Options
  • Documents

Specifications

Sampling Head and Flow

Filter Holder 37 mm
Detector Solid-state silicon (450 mm2 active area)
Pump Diaphragm-type, 7.0 LPM with no load

 

Data Analysis

  • MCA: 1024-channel analyzer binned to 256 channel spectrum
  • Alpha peak-shape fitting algorithm
  • 214Po, 218Po (optional 212Po) and two additional isotopes-of-interest
  • Acute (fast response) and Chronic (high sensitivity) dose determinations
  • Windows CE-based, 533 Mhz Intel X-Scale processor
  • Typical 28% efficiency for 239Pu

 

Physical

Temperature -17 to 50 °C (0 to 122 °F)
Humidity 5 to 100% (non-condensing); splash-proof electronics
Size (H x W x L) 25.4 x 30.5 x 12.7 cm (10 x 12 x 5 in.)
Weight 3.8 kg (8.3 lb)

Options

OptionDescriptionPart Number
RadNet Client Software Data/Status monitoring of up to 50 instruments simultaneously, requires RadNet Output option (PN 48-4352 or 48-4358). 88-4350
RadNet Output via WiFi Data/Status output over WiFi (RadNet protocol, internal antenna). 88-4352
RadNet Output via Ethernet Data/Status output over Ethernet (RadNet protocol). 88-4358
ASCII Output via RS-232 Data/Status output over RS-232 (ASCII protocol, RJ9 connector). 88-4356
ASCII Output via WiFi Data/Status output over WiFi (ASCII protocol, internal antenna). 88-4357
ASCII Output via Ethernet Data/Status output over Ethernet (ASCII protocol). 88-4359
External Pump Configuration Provides 10 mm (3/8 in.) hose barb for connection to external pump (not included) and removes standard internal pump and flow monitoring. 88-4353
In-Line Head (Remote Sampler) In-line head configuration to remote sample inlet up to 1.5 m (15 ft.), includes mass flow sensor, requires external pump (not included). 88-4355
Wireless Access Point 802.11b/g wireless access point, preconfigured for compatibility. 88-4349
1.5 µm Pore Speclon Filters Speclon PTFE membrane filters, size: 1.5 µm x 37 mm, box of 100. 88-4351

Documents

  • Data Sheet
  • Product Manual

Related Products

m334ab_front_angle21
Model 334AB-G
Results 1 - 1 of 1

Recently Viewed

m3-98-w-cable-2a-trans_500px
Model 3-98
m3030-2-face
Model 3030-2

Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.