Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Health Physics Medical Physics Metal Recycling Monitoring SystemsEmergency Response

Emergency Response

Emergency Response Kits

  • General Response Kits
  • Medical Response Kits
  • Decontamination Kits

Portal Monitors

No subcategories

Isotope Identifiers

No subcategories

Personal Radiation Meters

No subcategories

Friskers

No subcategories

Need Help?

Unsure about which instrument is best for your application?

Find your region's Ludlum representative or dealer.

  • US Contacts
  • International Contacts

OR

Contact Ludlum Sales:

(800) 622-0828 (USA Toll Free)

(325) 235-5494

Newsletter

Subscribe to our customer newsletter! Stay informed about Ludlum products and services, and get helpful support tips.

Please enable the javascript to submit this form

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

m2241-2rk_a_left_angle
m2241-2rk_a_left_anglem2241-2rk_b_frontm2241-2rk_c_right_angle

Model 2241-2RK

Emergency Response Kit CE Label

Part Number: 48-2829

Features

  • Ready-to-Go Kit
  • Measures Alpha-Beta-Gamma Contamination
  • Measures Exposure Rate
  • Includes a High-Sensitivity Gamma Probe for Quickly Finding Sources
  • Auto-Ranging Digital Scaler-Ratemeter

The 2241-2RK Emergency Kit packages all the basic radiation measurement tools needed to handle a radiological emergency into a convenient carrying case to facilitate a quick response when required. The kit includes the digital, auto-ranging, and versatile Model 2241-2 Scaler-Ratemeter that can measure exposure, contamination, and samples. Responders can either plug in the Model 44-9 alpha-beta-gamma GM pancake probe for contamination measurements and measuring samples, or the Model 44-2 high-sensitivity gamma scintillation detector for locating the source of high readings. A locked toggle switch selects the correct set of operating parameters for the detector currently connected to the instrument to optimize the measurement. A 137Cs check source is included to verify proper operation of the instruments along with a check source holder for convenient and secure accessibility. The rugged transport and storage case is foam-padded with cutouts in for each device and gives air- and watertight, corrosion-proof, and padlockable protection.

Ludlum offers several versions of pre-packaged response kits suitable for a wide variety of applications. If you desire more or different detectors, or other changes to our standard kits, please contact us regarding a customized kit. 

 

  • Specifications
  • Options
  • Documents
  • Specifications
  • Options
  • Documents

Specifications

m2241-2_bb-trans_500px
Model 2241-2
Scaler-Ratemeter

m44-2
Model 44-2
Gamma Detector

m44-9_profile
Model 44-9
Alpha-Beta-Gamma Detector

cs-137_0_25microci
Plastic Disk Check Sources


check-source-holder-closed
Mechanical Check Source Holder


Case Size & Weight

Size (H x W x L) 46.5 x 35 x 17.8 cm (18.3 x 13.8 x 7 in.)
Weight 5.9 kg (13 lb) (with instruments)

Options

OptionDescriptionPart Number
m3000-series-shoulder-strap
Shoulder Strap
Adjustable nylon shoulder strap. 4363-413
Headphone Jack
Adds headphone jack to instrument. 4464-464
stereo_mono_headphones
Stereo/Mono Headphones
Adjustable stereo/mono headphones. 22-9313
m2002-1050ambdosefilter
Dose Filter
The GM pancake detector has a significant over-response at lower energies, producing dose measurement errors. The dose filter flattens the response to within ± 20% referenced to 137Cs (662 keV) over the energy range of 20 keV to 1.2 MeV. 2002-1050

Documents

  • Data Sheet
  • Product Manual
  • PC Data Logging Software
  • PC Data Logging Software Data Sheet
  • CE Certificate

Related Products

emergency_respon_4b90241f8728b
Model 14C-RK
medical_env__res_4c44a8bbbacf5
Model 2241-3MERK
m3-is_norm_kit
Model 3-IS NORM Kit
m2241-3rk2_open_front
Model 2241-3RK2
m3001-2rk_-_rev
Model 3001-2RK
m3001-3rk2_-_rev
Model 3001-3RK
Results 1 - 6 of 6

Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.