Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Health Physics Medical Physics Metal Recycling Monitoring SystemsEmergency Response

Emergency Response

Emergency Response Kits

  • General Response Kits
  • Medical Response Kits
  • Decontamination Kits

Portal Monitors

No subcategories

Isotope Identifiers

No subcategories

Personal Radiation Meters

No subcategories

Friskers

No subcategories

Need Help?

Unsure about which instrument is best for your application?

Find your region's Ludlum representative or dealer.

  • US Contacts
  • International Contacts

OR

Contact Ludlum Sales:

(800) 622-0828 (USA Toll Free)

(325) 235-5494

Newsletter

Subscribe to our customer newsletter! Stay informed about Ludlum products and services, and get helpful support tips.

Please enable the javascript to submit this form

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

m3014
m3014m3014_rightm3014_leftm3014_top_1610790389

Model 3014

Dual-Detector Digital Survey Meter / SCA

Features

  • Internal Gamma Detector for Survey / Accumulated Dose
  • Can Be Used with a Variety of External Detectors
  • General Purpose Survey Meter
  • Rate, Max, Integrated Dose, and Count Modes
  • Alpha, Beta, or Alpha+Beta Capable
  • Single Channel Analyzer (SCA) Capable
  • Large Backlit LCD for Ease of Reading
  • 4-Button Intuitive Interface for Easy Operation
  • 1-Button Handle Interface for Data Logging
  • Digital Calibration, Data Logging, Auto-Ranging, USB
  • Bluetooth, True RS-232, and Headphone Options
  • Alternative to Ludlum Models 14C and 2221

The Ludlum Model 3014 is a durable, lightweight instrument with both an internal energy-compensated gamma detector and a connection for an external detector. It features a large, easy-to-read LCD screen and audible alarms and is controlled using a simple five-button interface. The unit body is made of high-impact plastic and splash-resistant construction allows the instrument to be used outdoors.

Four modes of operation are available – RATE, MAX, INTG, and COUNT – which can be selected by pressing the MODE button. Measurements can be collected in two sets of units (primary and secondary) for RATE and MAX modes. The user can switch between the two sets of units by pressing the UNITS button. Pressing the DETECTOR button toggles the display between the internal and external detector readings. When enabled with the Lumic Data Logger Kit (see Options), data can be logged in any of the operational modes using the LOG button on the handle. Up to 1000 data points can be stored internally. The SCA ability allows a scintillator or proportional detector to be set up with an upper window, giving it higher sensitivity to a specific isotope or region. This instrument can be used with external alpha-beta detectors to display alpha, beta, or alpha+beta counts.

Instrument setup can be done either through the front-panel controls or via the Lumic Calibration Kit (see Options). The Model 3014 is shipped ready to use with batteries and calibration certificate.

 

  • Specifications
  • Configurations
  • Options
  • Documents
  • Firmware Updates
  • Specifications
  • Configurations
  • Options
  • Documents
  • Firmware Updates

Specifications

Internal Detector Energy compensated GM or scintillation detector
Internal Detector Range See Configurations tab for available ranges
Compatible External Detectors GM, scintillation, proportional, or neutron detectors
High Voltage 300 to 2400 Vdc
Linearity Readings within 10% of true value
Modes Four operational modes including rate, max, integrated dose, and count
Display 3-digit auto-ranging LCD with large 20 mm (0.8 in.) digits.
Units: (k)(M)c, (k)cps, (k)(M)cpm, (k)(M)d, (k)(M)Bq, (k)(M)Bq/cm2, (k)(M)dpm, (µ)(m)(k)(M)R, (µ)(m)(k)R/h, (µ)(m)(k)(M)Sv, (µ)(m)Sv/h, (µ)(m)(k)(M)Rem, (µ)(m)(k)Rem/h.
Indicators: bar graph, radiation type (alpha (α), beta (β), gamma (γ), neutron (n)), mode (MAX, INTG), three alarm levels (ALARM 1, 2, 3), fault messages (FAULT, OVERLOAD, LOSS OF COUNT, OVERRANGE), USB, wireless, audio, and low-battery.
Display Range
  • 00.0 cps to 999 kcps
  • 00.0 cpm to 99.9 Mcpm
  • 00.0 Bq to 999 MBq
  • 00.0 Bq/cm2 to 999 MBq/cm2
  • 00.0 dpm to 999 Mdpm
  • 0.00 µR to 999 MR
  • 0.00 µR/h to 9.99 kR/h
  • 0.00 µSv to 999 MSv
  • 0.00 µSv/h to 999 Sv/h
  • 0.00 µRem to 999 MRem
  • 0.00 µRem/h to 9.99 kRem/h
  • 0 c to 999 Mc (counts)
  • 0 d to 999 Md (disintegrations)
Operational display ranges are dependent on the detector and dead time configuration. The minimum and maximum display can be set to limit the display to the calibrated range.
Backlight Built-in ambient light sensor automatically activates LED backlight unless internal dipswitch is set to continuous-on
Controls
  • ON/AUD: Extra-long press to turn ON; Short press to adjust audio level; Extra-long press to turn OFF
  • UNITS: Short press changes the units between count rate, dose/exposure, or disintegration
  • DETECTOR: Short press to change between the external and internal detector
  • MODE: Short press alternates between modes: RATE (displays count rate), MAX (captures peak rate), COUNT (user-selectable preset count time from 0 to 31.68 years), and DOSE (current accumulated dose)
  • LOG: Short press to log current display (requires Lumic Data Logger Kit, see Options) or initiate count in COUNT mode, extra-long press to change count in COUNT mode
Data Logging Can store up to 1000 data points internally. Requires Lumic Data Logger Kit (see Options)
Response Time User-selectable from 1 to 60 seconds, auto SLOW, auto FAST, fixed SLOW (22 s), fixed FAST (4 s)
Alarms Three count rate, exposure/dose, scaler, and accumulated dose alarm set-points adjustable over the display range
Self-Diagnostics Detects and reports internal instrument issues, indicated by graphic FAULT display and audio warning
Overload Protection High rate saturation protection prevents false display of lower count rates. OVERLOAD will appear on the display and an audio warning will be triggered.
Loss of Count Protection After a user defined time, typically 60 seconds, with no pulses from detector, the unit will flash a zero reading, an audio warning will be triggered, and LOSS OF COUNTS will appear on the display
Overrange If reading should exceed the predefined detector range, the unit will flash a maximum reading, an audio warning will be triggered, and OVERRANGE will appear on the display
Audio "Click" audio greater than 65 dB at 0.6 m (2 ft.), Alarm audio greater than 72 dB at 0.6 m (2 ft), approximately 4.5 kHz
Calibration Protection Internal dipswitch to disable front-panel calibration parameter changes
Power Four "AA" batteries
Battery Life Approximately 175 hours of operation, 16-hour low battery warning
Construction High-impact polycarbonate with rubber seals and separate battery compartment
Temperature Range -20 to 50 °C (-5 to 122 °F), may be certified for operation from -40 to 65 °C (-40 to 150 °F)
Environmental Rating NEMA rating of 3x or IP rating of 53
Size (H x W x L) 16.5 x 11.4 x 21.6 cm (6.5 x 4.5 x 8.5 in.)
Weight 0.9 kg (2.0 lb) (excluding detectors and clips)

 


Configurations

ModelInternal Detector / RangePart Number
3014 Energy compensated GM
Background to 50 mSv/h (5 R/hr)
48-4365
3014/1 CsI scintillator
Background to 500 µSv/h (50 mR/hr)
48-4365-1
3014/3 Energy compensated GM
Background to 250 mSv/h (25 R/hr)
48-4365-3
3014/4 Energy compensated GM
Background to 500 mSv/h (50 R/hr)
48-4365-4
3014/6 Energy compensated GM
Background to 1 Sv/h (100 R/hr)
48-4365-6

Options

OptionDescriptionPart Number
Lumic Calibration Kit
Lumic Calibration Software allows the reading and writing of important parameters via a USB port in the Model 3000 Series and Model 30 family of instruments. This software also includes a calibration wizard (guides the user through calibration steps) and a plateau wizard (determines the optimal detector operating voltage).

The kit includes Lumic Calibration Software versions 1.0 and 2.0, a Model 3000 Series USB cable, and a Model 30 family USB cable.
4519-865
Lumic Configuration Kit
Lumic Configuration Software allows the reading and writing of important parameters via a USB port in the Model 3000 Series and Model 30 family of instruments. Does not include calibration or plateau wizards.

The kit includes the Lumic Configuration Software, a Model 3000 Series USB cable, and a Model 30 family USB cable.
4519-747
Lumic Data Logger Kit
(Model 3000-Series)
Includes Lumic Data Logger Software and cable. 4498-1019
worker_w_phone--instrument7
Model 3000 Series
Bluetooth® Option & Lumic Linker
Wirelessly connects the instrument with an Android or iOS mobile device. 4519-564
RS232 serial optionRS-232 Serial Port Adds a true RS-232 serial port connector. 4519-594
TTL serial optionTTL Serial Port Adds TTL 3.3 V serial port connector. Available modes are instrument dependent, contact us for more information on configuration options. 4519-595
Headphone Jack
Adds a headphone jack to the instrument. 4498-555
stereo_mono_headphones
Stereo/Mono Headphones
Adjustable stereo/mono headphones. 22-9313
M3000 Series with Strap
Shoulder Strap
1.8 m (6 ft) adjustable nylon shoulder strap. Requires instrument case modification. 4498-868
m2312958_open
Model 3000-Series Case
Rugged, dust- and waterproof transport and storage case. 2312958

Documents

  • Data Sheet
  • Product Manual
  • CE Certificate
  • Model 3000 Series Comparison Table
  • Options for Model 3000 Series

Firmware Updates

In order to use the latest Lumic Calibration Software*, you may need to update the firmware on your instrument. (All new instruments will be compatible with the latest software version.) Use the table below to determine the firmware requirement for your instrument.

Software Version Compatible Models Required Firmware
Lumic 1.0 30, 30-4, 30-6, 30-7, 35, 79 2.x or lower
3000, 3001, 3005, 3006, 3019, 3276 N34 or lower
3002, 3277 N12 or lower
Lumic 2.0 30, 30-4, 30-6, 30-7, 35, 79 3.x or higher
3000, 3001, 3005, 3006, 3019, 3276 N40 or higher
3002 N20 or higher
3003, 3014, 3078 N/A

*Note: If you purchased the original Lumic 1.0 software, you are eligible for a free copy of Lumic 2.0. Please contact your local sales representative or Ludlum Measurements to receive your copy.


To update the firmware on your instrument:
  1. Download the appropriate instructions file (PDF) for your instrument.
    IMPORTANT: The firmware update instructions are model number specific. You must use the instructions for your specific instrument model. See table below.

    Model Instructions File
    30, 30-4, 30-6, 30-7, 35, 79 Lumic Firmware Update Instructions (Model 30/35/79 Series)
    3000, 3001, 3002, 3005, 3006, 3019, 3276 Lumic Firmware Update Instructions (Model 3000 Series, Gen 1)
    3003, 3014, 3078 Lumic Firmware Update Instructions (Model 3000 Series, Gen 2)
  2. Download the latest Lumic Firmware Updater Software.
  3. Determine the printed circuit board number your instrument has. To do this, you must open the instrument can and find the number on the circuit board.
  4. Using the drop-down selectors below, select your instrument model and printed circuit board number. This will populate a list of available firmware downloads for your instrument.

Related Products

m14c-lftt-angle-trans500px
Model 14C
m3003_web
Model 3003 Series
m3001_face_w_log-button--handle-1b
Model 3001
m3-lft-angle-w-handle-4-trans-merged_500px
Model 3
m3002_frontrtangleview_500
Model 3002
m3000_angle1
Model 3000
m3a-lft-angle-trans_500px
Model 3A
Results 1 - 7 of 7

Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.