Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Health Physics Medical Physics Metal Recycling Monitoring SystemsEmergency Response

Health Physics

Portable Survey Meters

  • Friskers
  • General Purpose - Digital
  • General Purpose - Analog
  • Computerized
  • Data Loggers
  • Specialized Meters
  • Geiger Counters
  • Intrinsically Safe
  • Ion Chambers
  • Isotope Identifiers
  • microR / microSv Meters
  • Extended Reach microR / microSv Meters
  • Neutron Meters
  • Pocket-Size Meters
  • Scaler-Ratemeters
  • Stretch Scopes

Personal Radiation Meters

No subcategories

Benchtop Meters

No subcategories

Scalers / Counters

No subcategories

Pulsers

No subcategories

Detectors

  • Alpha
  • Alpha-Beta
  • Alpha-Beta-Gamma
  • Beta
  • Gamma GM
  • Gamma Scintillator
  • Low-Energy Gamma Scintillator
  • Neutron
  • Waterproof Detectors
  • Pipe Detectors
  • Sample Counter Heads
  • Sample Holders

Monitoring Systems

  • Area Monitor Controllers
  • Area Monitoring Systems
  • Portal Monitors
  • Monitoring Systems
  • Contamination Monitors
  • Article Monitors
  • Air Monitors
  • Hand & Foot Monitors
  • Body Monitors
  • Vehicle Monitors
  • Scrap Monitoring Systems
  • Laundry Monitors

Ground/Floor Surveying

No subcategories

Sample Counting

  • Sample Counting Systems
  • Scalers / Counters
  • Sample Counter Heads
  • Protean Instrument Alpha-Beta Counting Systems

Tritium Monitoring

No subcategories

NORM Kits

No subcategories

Dosimetry

  • Dosimeters
  • Dosimeter Accessories

Accessories

  • Detector Accessories
  • Handles & Straps
  • Audio
  • Cables, Connectors & Signal Convertors
  • Check Sources
  • Instrument Cases

Need Help?

Unsure about which instrument is best for your application?

Find your region's Ludlum representative or dealer.

  • US Contacts
  • International Contacts

OR

Contact Ludlum Sales:

(800) 622-0828 (USA Toll Free)

(325) 235-5494

Newsletter

Subscribe to our customer newsletter! Stay informed about Ludlum products and services, and get helpful support tips.

Please enable the javascript to submit this form

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

m26-2-angle
m26-2-anglem26-2-faceModel 26-2

Model 26-2

Integrated Frisker with Timed Frisk

Part Number: 48-4044

Features

  • Integrated, Lightweight Design
  • High-Impact Plastic with Water-Resistant Rubber Seals
  • GM Pancake Detector
  • Ratemeter, Peak, and Timed Frisk Operating Modes
  • Simple Two-Button Operation
  • Automatic LCD Backlight
  • Comfortable Non-Slip Grip, Includes Lanyard & Adjustable Wrist Strap
  • Daylight-Visible Green & Red Status LEDs

Frisking people and objects for alpha and beta contamination has always been a little awkward because manipulation of the detector and the electronics required the use of both hands. The cable-less Model 26-2 consolidates the electronics and the detector into one ergonomic housing. This optimized configuration incorporates a standard GM pancake detector and large auto-ranging LCD display into one convenient package, making it easier than ever to detect contamination. 

Operation is simplified through the use of just two buttons. The MAX mode feature, which captures the highest or peak count rate, is particularly convenient whenever the display is not directly visible. The timed frisk mode allows the user to frisk for a fixed time interval. This instrument incorporates low power circuitry, delivering hundreds of hours of use with just two standard “AA” size batteries. The calibrator can protect parameters (cps/cpm, response time, alarm points, and frisk time) or allow the user to adjust them.

 

  • Specifications
  • Graphs
  • Options
  • Documents
  • Specifications
  • Graphs
  • Options
  • Documents

Specifications

Detector Pancake GM detector, stainless steel screen
Window Area Active: 15.51 cm2
Open: 12.26 cm2
Efficiency (4π)

Alpha
239Pu: 11%

Beta
99Tc: 14%
32P: 32%
14C: 2%
90Sr/90Y: 22%
125I: 0.2%

Gamma
5.5 cps per µSv/hr (3300 cpm per mR/hr) (137Cs)
99mTc: ≤ 1%

Display 3½ digit LCD with large 12.7 mm (0.5 in. ) digits, low-battery indicator, MAX, ALARM
Units: (k)cps, (k)cpm
Range
  • 0.1 cps to 1.99 kcps
  • 1 cpm to 99.9 kcpm
Linearity ± 10%
Backlight Built-in ambient light sensor automatically activates low-power LED backlight. May be configured for 'Continuous On' operation (will reduce battery life).
LEDs
  • Daylight-visible green LED for "OK"
  • 3 red LEDs for 3 levels of alarm
Controls
  • ON / OFF / QUIET: Press to turn ON; Tap to alternate between 'click' audio and QUIET; Hold for OFF
  • MODE: Alternates between NORMAL (count rate), MAX (captures peak rate), and TIMED FRISK (user-selectable preset count time from 0 to 20 min.)
Response Time User-selectable from 1 to 60 seconds or Auto-response rate FAST or SLOW
Resolving Time Approximately 110 µs as defined by IEC 60325
Alarms Up to three count rate alarm setpoints, adjustable over the display range
Overload Protection High count rate saturation protection prevents false display of lower count rates
Loss of Count Protection After 60 seconds of no pulses from detector, unit will flash a zero reading and the alarm audio will be triggered
Click Audio Greater than 60 dB at 0.6 m (2 ft)
HV Testpoint Accessible by removing battery cover, allows HV measurement and pulse injection for calibration using optional cable (PN: 8303-1044)
Temperature Range -20 to 50 °C (-4 to 122 °F)
May be certified for operation from -40 to 65 °C (-40 to 150 °F)
Environmental Rating NEMA 3 / IP 53
Power Two 'AA' batteries
Battery Life Approximately 250 hours of operation, 16-hour low battery warning
Construction High-impact polycarbonate plastic with water-resistant rubber seals, separate battery compartment, and rubber overmold
Distance from Surface Plane to Screen 0.32 cm (0.125 in.)
Size (H x W x L) 4.6 x 6.9 x 27.2 cm (1.8 x 2.7 x 10.7 in.)
Weight 0.45 kg (1.0 lb)

Graphs

44-9 & 26 Series Beta Efficiency


Options

OptionDescriptionPart Number
Protective Cover with Tether Adds tether to the detector protective cover to keep attached to instrument when cover is not in use. 4519-041
Headphone Jack
Adds headphone jack to instrument. 4498-538
M26 holsterM26 holster open
Canvas Holster
Canvas holster with belt clip for Model 26 Series instruments. 2312577
m180-28_angle73
Model 180-28
Sample holder for Model 26-Series friskers. 47-3948
Calibration Cable Allows HV measurement and pulse injection into any Model 26 family of instruments (excluding the Model 26S) from 2019 and later. 99 cm (39 in.) long, C to test pin. 8303-1044
Person holding extendable pole with Model 26 frisker attachedExtendable Pole

A lightweight pole with 5 telescoping sections and an adjustable clamp to hold a Model 26 Series Frisker. Useful to access high, low, or other hard to reach places.

Length: 0.55 m (1.8 ft) collapsed, 1.5 m (4.92 ft) fully extended

4519-077
case_m2311064_large

Transport & Storage Case for
Model 26 and Extendable Pole
Rugged, waterproof, airtight, hard-shell case with dense foam padding to hold Model 26 and extendable pole. 2311064

Documents

  • Data Sheet
  • Product Manual
  • Model 26 Series Comparison Table

Related Products

m26-angle
Model 26
m26-1-series
Model 26-1 Series
m26-3
Model 26-3
Model 26S Integrated Scintillator Frisker
Model 26S
Results 1 - 4 of 4

Recently Viewed

m26-3
Model 26-3

Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.