Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Health Physics Medical Physics Metal Recycling Monitoring SystemsEmergency Response

Health Physics

Portable Survey Meters

  • Friskers
  • General Purpose - Digital
  • General Purpose - Analog
  • Computerized
  • Data Loggers
  • Specialized Meters
  • Geiger Counters
  • Intrinsically Safe
  • Ion Chambers
  • Isotope Identifiers
  • microR / microSv Meters
  • Extended Reach microR / microSv Meters
  • Neutron Meters
  • Pocket-Size Meters
  • Scaler-Ratemeters
  • Stretch Scopes

Personal Radiation Meters

No subcategories

Benchtop Meters

No subcategories

Scalers / Counters

No subcategories

Pulsers

No subcategories

Detectors

  • Alpha
  • Alpha-Beta
  • Alpha-Beta-Gamma
  • Beta
  • Gamma GM
  • Gamma Scintillator
  • Low-Energy Gamma Scintillator
  • Neutron
  • Waterproof Detectors
  • Pipe Detectors
  • Sample Counter Heads
  • Sample Holders

Monitoring Systems

  • Area Monitor Controllers
  • Area Monitoring Systems
  • Portal Monitors
  • Monitoring Systems
  • Contamination Monitors
  • Article Monitors
  • Air Monitors
  • Hand & Foot Monitors
  • Body Monitors
  • Vehicle Monitors
  • Scrap Monitoring Systems
  • Laundry Monitors

Ground/Floor Surveying

No subcategories

Sample Counting

  • Sample Counting Systems
  • Scalers / Counters
  • Sample Counter Heads
  • Protean Instrument Alpha-Beta Counting Systems

Tritium Monitoring

No subcategories

NORM Kits

No subcategories

Dosimetry

  • Dosimeters
  • Dosimeter Accessories

Accessories

  • Detector Accessories
  • Handles & Straps
  • Audio
  • Cables, Connectors & Signal Convertors
  • Check Sources
  • Instrument Cases

Need Help?

Unsure about which instrument is best for your application?

Find your region's Ludlum representative or dealer.

  • US Contacts
  • International Contacts

OR

Contact Ludlum Sales:

(800) 622-0828 (USA Toll Free)

(325) 235-5494

Newsletter

Subscribe to our customer newsletter! Stay informed about Ludlum products and services, and get helpful support tips.

Please enable the javascript to submit this form

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

pc_based_gamma_m_4d40626815015
pc_based_gamma_m_4d40626815015roi_analysis_png_671608988saas_screen1_png_1585540488

Model 733

PC-Based Gamma MCA System

Part Number: 48-3835

Features

  • 1k Multi Channel Analyzer
  • 7.6 x 7.6 cm (3 x 3 in.) NaI(Tl) Detector
  • USB PC Interface
  • Includes PC Spectrum Acquisition & Analysis Software 

The Model 733 is an affordable PC-based gamma spectroscopy system conveniently packaged to run directly on your PC. The system includes a detector, USB cable, and PC Spectrum Acquisition & Analysis Software (SAAS). The Model 733 gamma detector is a combined MCA, HV Power Supply and 7.6 x 7.6 cm (3 x 3 inch) NaI(Tl) scintillator. Ludlum also offers a Model 732 that is identical, except it incorporates a smaller 5.1 x 5.1 cm (2 x 2 inch) NaI(Tl) scintillator. The detector receives its power directly from the PC via the USB interface so no extra cables are required.  

The MCA is equipped with 1024 channels and utilizes a 10-bit Wilkinson type ADC. Spectra are acquired and then sent via the USB interface to the PC once every second where they are analyzed and stored by the SAAS software. The SAAS software package is a very basic and user-friendly program that facilitates spectrum acquisition and analysis. Once calibrated, the user can acquire live streaming data or previously stored spectra and perform peak analysis, select user-defined ROIs, and exercise spectrum stabilization, stripping, smoothing, and normalization math routines. Spectral data can also be exported to more powerful MCA programs to perform additional quantitative and qualitative analysis for determining the activity and isotope identification.

 

  • Specifications
  • Documents
  • Specifications
  • Documents

Specifications

Detector

Detector NaI(Tl) scintillator, 7.6 x 7.6 cm (3 x 3 inch) 
Typical Sensitivity 3800 cps per µSv/h (2300 cpm per µR/hr)
PMT 14-pin base voltage divider with preamplifier
Interface USB
USB Cable Length 5 m (16.4 ft)
Power Draw Approximately 4.75 V at 450 mA via PC USB interface
Size (D x L) 8.3 x 24.1 cm (3.25 x 9.5 in.)
Weight 1.8 kg (4 lb)
Overall Size with MCA (D x L) 8.3 x 34.9 cm (3.25 x 13.7 in.)

 

MCA Specifications

MCA 1024 channels
HV Supply 0 to 1200 Vdc at 0.5 mA ripple < 30 mV
HV Adjust Software selectable
Spectroscopy Amplifier 1 μs semi-Gaussian shaping with internal PZ adjustment
Gain Setting for Amplifier Software selectable
Output 0 to 5 Vdc unipolar semi-Gaussian connected internally to ADC input
Interface USB
ADC Specifications ADC Type: 1k channel 10 bit Wilkinson
Clock Frequency: 48 MHz
Conversion Time: 20 μs for FS input
ADC Control: Through Silab F340 micro controller via USB interface
Differential Non Linearity: 2%
LLD Setting: Software selectable
Power Supply: From USB port of PC/Laptop

 

Spectrum Acquisition and Analysis Software (SAAS)

PC Requirements
(PC not supplied)
  • 2 GB RAM, 80 GB hard disk
  • Windows XP™ or higher operating system
  • .NET version 3.5 (supplied on installation CD)
  • Microsoft Office 2007 (Excel application for nuclear library)
  • USB port version 2.0
  • Display resolution of at least 1024 x 780 pixels
Energy Peak Search Identifies each peak energy as an ROI (does not identify isotope)
ROI Analysis Start/Stop channel, Centroid, FWHM, Integral, Background, Area, Error, Counts/Channel
Math Functions Smoothing, Normalization, Stripping
Controls File up to 3 active buffers
Acquisition Preset time between 1 to 999,999,999 s
Spectrum Expand, Contract, Scale up/down, Stabilization
ROI Select start and end energy regions, delete ROI
Calibration User selectable 2 or 3 energy points
File Type ANSI N42 for exporting to more powerful qualitative (isotope identification) and quantitative analysis (source activity) software - SAAS type S1000

Documents

  • Data Sheet
  • Product Manual

Related Products

pc_based_gamma_m_4d405bec91fa5
Model 732
Results 1 - 1 of 1

Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.