Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Health Physics Medical Physics Metal Recycling Monitoring SystemsEmergency Response

Medical Physics

Radiation Safety QA

  • Friskers
  • Survey Meters
  • Ion Chambers
  • Neutron Meters
  • Isotope Identifiers
  • Scaler-Ratemeters
  • Personal Radiation Meters
  • Scalers / Counters
  • Response Kits
  • Area Monitors
  • Portal Monitors
  • Personnel Monitoring
  • Dosimeters
  • Shielding

Imaging QA Test Tools

No subcategories

CT / MRI QA

No subcategories

Mammography QA

No subcategories

Ultrasound QA

No subcategories

Nuclear Medicine QA & Safety

No subcategories

Need Help?

Unsure about which instrument is best for your application?

Find your region's Ludlum representative or dealer.

  • US Contacts
  • International Contacts

OR

Contact Ludlum Sales:

(800) 622-0828 (USA Toll Free)

(325) 235-5494

Newsletter

Subscribe to our customer newsletter! Stay informed about Ludlum products and services, and get helpful support tips.

Please enable the javascript to submit this form

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

m30-4_angle
m30-4_angleModel 30-4m30-4_frontm30-4_sidem30-4_bottom_web

Model 30-4

Digital Neutron Survey Meter

Part Number: 48-4191

Features

  • Multi-Function Digital Display Unit
  • Low-Weight Device Substitutes for Ratemeter
  • Simple Switching Between Two Sets of Measurement Units
  • Moderated Neutron Detector
  • Range: 0 to 99.9 mSv/h (0 to 9.99 rem/hr)
  • Display Unit Detaches for Greater Versatility

The Ludlum Model 30-4 joins the Model 30 digital display unit with a 22.9 cm (9 in.) REM ball containing a 3He detector, thereby providing a significant weight reduction and more compact, maneuverable instrument for determining neutron dose rates.Three modes of operation – RATE, MAX, and COUNT – are available for the user. Measurements can be collected in two sets of units (primary and secondary) for RATE and MAX modes in cps, cpm, rem/hr, or Sv/h units. An internal switch is used to enable or disable the front-panel setup feature to protect desired settings from inadvertent modification. Setup is also available via software from Ludlum Measurements.

This instrument features a large, easily-readable LCD (liquid crystal display) that may be rotated for maximum ease of use for the operator. The connecting cable is threaded through the rugged carrying handle to simplify use. In addition the display unit may be detached from REM ball permitting the operator to position the detector and the display unit to best advantage within the limits of the cable length. Other features are an audio warning tone and easy, intuitive, user-friendly design. Splash-resistant construction allows the Model 30 to be used in outdoor environments. The instrument body is constructed of lightweight, durable, high-impact plastic.

 

  • Specifications
  • Options
  • Documents
  • Firmware Updates
  • Specifications
  • Options
  • Documents
  • Firmware Updates

Specifications

Indicated Use Neutron dose rate 
Detector 3He proportional detector, 1.6 x 2.5 cm (0.6 x 1.0 in.) (D x L), surrounded by a 22.9 cm (9.0 in.) diameter cadmium loaded polyethylene sphere
Measurement Range 0 to 99.9 mSv/h (0 to 9.99 rem/hr)
Sensitivity (bare AmBe neutrons) Typically 10 cpm per μSv/h (100 cpm per mrem/hr) 
Energy Response Provides approximate inverse RPG curve for neutrons from thermal through 7 MeV, provides response up to 12 MeV
Linearity Reading within 10% of actual value
Gamma Rejection (137Cs gamma) < 10 cpm through 0.1 Sv/h (10 R/hr) 
LCD Display 3 digit LCD with large 13.4 mm (0.53 in.) digits, low-battery indicator, MAX, ALARM, MUTE
Units: (k)cps, (k)cpm, (µ)(m)Sv(/h), (µ)(m)rem(/h)
Display Range
  • 0.0 cps to 99.9 kcps
  • 0.00 cpm to 999 kcpm
  • 0.00 µrem/hr to 999 rem/hr
  • 0.00 µSv/h to 999 Sv/h
Display range can be set to limit display to calibrated range
Backlight Built-in ambient light sensor automatically activates low-power LED backlight, unless internal dipswitch is set to continuous-On (will reduce battery life). Alarm light intensity varies based on ambient light levels.
Controls
  • ON/OFF/ACK: Long press to turn ON; Tap to acknowledge alarms and silence alarm tone; Press to reset Sigma Audio alarm, turn “click” audio On/Off, turn Sigma Audio beep On/Off; Press and hold for OFF
  • MODE: Long press alternates between NORMAL (count rate), MAX (captures peak rate), COUNT (user-selectable preset count time from 0 to 10 min.). Number of modes can be reduced in setup.
  • UNITS: Long press changes the units between count rate (cpm, cps) or dose/exposure (µSv/h, rem/hr)
Response Time User-selectable from 1 to 60 s, Auto-Response Rate FAST or SLOW, or Fixed FAST and SLOW
Alarms Count rate, exposure/dose, and scaler alarm setpoints adjustable over the display range
Overload High count rate saturation protection prevents false display of lower count rates
Dead Time Correction Employs first and second order corrections for extended performance
Operating Voltage Approximately 1200 Vdc
Threshold -2 mV
Audio Greater than 75 dB at 0.6 m (2 ft), approximately 4 kHz
Click Audio Divide x1, x10, x100, x1k
Power Two alkaline or two rechargeable “AAA” batteries
Battery Life Approximately 100 hours of operation, 24-hour low battery warning
Construction High-impact plastic with water-resistant rubber seals and separate battery compartment
Working Environment Splashproof shields for outdoor use
Temperature Range -20 to 50 °C (-5 to 122 °F)
May be certified for operation from -40 to 65 °C (-40 to 150 °F)
Environmental Rating NEMA rating of 3x or IP rating of 52 with audio hole seal option (hole seal option will reduce maximum volume by approximately 10 dB)
Size Display Unit: 8.5 x 8.0 x 4.8 cm (3.4 x 3.1 x 1.9 in.) (H x W x L)
Detector: 22.9 cm (9 in.) diameter REM ball with 3He detector (1.6 x 2.5 cm)(D x L)
Weight Display Unit: 174 g (0.38 lb)
REM Ball Component: 6.6 kg (14.5 lb)

Options

OptionDescriptionPart Number
Lumic Calibration Kit
Lumic Calibration Software allows the reading and writing of important parameters via a USB port in the Model 3000 Series and Model 30 family of instruments. This software also includes a calibration wizard (guides the user through calibration steps) and a plateau wizard (determines the optimal detector operating voltage).

The kit includes Lumic Calibration Software versions 1.0 and 2.0, a Model 3000 Series USB cable, and a Model 30 family USB cable.
4519-865
Lumic Configuration Kit
Lumic Configuration Software allows the reading and writing of important parameters via a USB port in the Model 3000 Series and Model 30 family of instruments. Does not include calibration or plateau wizards.

The kit includes the Lumic Configuration Software, a Model 3000 Series USB cable, and a Model 30 family USB cable.
4519-747
Headphone Jack
Adds headphone jack to instrument. 4498-697
case_web
Case for Neutron Meters
Rugged transport and storage case. 2310377
2311487-neutron-case_600px
Case for Neutron Meters
Rugged transport and storage case. Has wheels and extendable handle. 2311487

Documents

  • Data Sheet
  • Product Manual (Model 30)
  • CE Certificate
  • Ludlum Neutron Meters Comparison Table

Firmware Updates

In order to use the latest Lumic Calibration Software*, you may need to update the firmware on your instrument. (All new instruments will be compatible with the latest software version.) Use the table below to determine the firmware requirement for your instrument.

Software Version Compatible Models Required Firmware
Lumic 1.0 30, 30-4, 30-6, 30-7, 35, 79 2.x or lower
3000, 3001, 3005, 3006, 3019, 3276 N34 or lower
3002, 3277 N12 or lower
Lumic 2.0 30, 30-4, 30-6, 30-7, 35, 79 3.x or higher
3000, 3001, 3005, 3006, 3019, 3276 N40 or higher
3002 N20 or higher
3003, 3014, 3078 N/A

*Note: If you purchased the original Lumic 1.0 software, you are eligible for a free copy of Lumic 2.0. Please contact your local sales representative or Ludlum Measurements to receive your copy.


To update the firmware on your instrument:
  1. Download the appropriate instructions file (PDF) for your instrument.
    IMPORTANT: The firmware update instructions are model number specific. You must use the instructions for your specific instrument model. See table below.

    Model Instructions File
    30, 30-4, 30-6, 30-7, 35, 79 Lumic Firmware Update Instructions (Model 30/35/79 Series)
    3000, 3001, 3002, 3005, 3006, 3019, 3276 Lumic Firmware Update Instructions (Model 3000 Series, Gen 1)
    3003, 3014, 3078 Lumic Firmware Update Instructions (Model 3000 Series, Gen 2)
  2. Download the latest Lumic Firmware Updater Software.
  3. Determine the printed circuit board number your instrument has. To do this, you must open the instrument can and find the number on the circuit board.
  4. Using the drop-down selectors below, select your instrument model and printed circuit board number. This will populate a list of available firmware downloads for your instrument.

Related Products

m30_face_133764959
Model 30
m30-7
Model 30-7 Series
m3007-angle
Model 3007 Series
m12-4-7_no_bkg_500
Model 12-4-7
m12-4a
Model 12-4
2241-4_neutron_mete_cmyk_500px
Model 2241-4
m375-31h_pic-8-trans-a-merged
Model 375-31H
m2363-w-prescila8
Model 2363 with 42-41L
m15-lft-angle-trans-lower-detector-5-merged_500px
Model 15
Results 1 - 9 of 9

Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.