Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Health Physics Medical Physics Metal Recycling Monitoring SystemsEmergency Response

Medical Physics

Radiation Safety QA

  • Friskers
  • Survey Meters
  • Ion Chambers
  • Neutron Meters
  • Isotope Identifiers
  • Scaler-Ratemeters
  • Personal Radiation Meters
  • Scalers / Counters
  • Response Kits
  • Area Monitors
  • Portal Monitors
  • Personnel Monitoring
  • Dosimeters
  • Shielding

Imaging QA Test Tools

No subcategories

CT / MRI QA

No subcategories

Mammography QA

No subcategories

Ultrasound QA

No subcategories

Nuclear Medicine QA & Safety

No subcategories

Need Help?

Unsure about which instrument is best for your application?

Find your region's Ludlum representative or dealer.

  • US Contacts
  • International Contacts

OR

Contact Ludlum Sales:

(800) 622-0828 (USA Toll Free)

(325) 235-5494

Newsletter

Subscribe to our customer newsletter! Stay informed about Ludlum products and services, and get helpful support tips.

Please enable the javascript to submit this form

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

m3000_angle1
m3000_angle1m3000_angle2m3000_sidem3000_topm3000_w_m44-9_datasheetm3000-w-44-2

Model 3000

Digital Survey Meter

Part Number: 48-4035

Features

  • Large, Backlit, Easy-To-Read LCD Screen
  • Auto-Ranging
  • RATE, MAX, and COUNT Modes of Operation
  • Splash-Resistant Construction for Outdoor Use
  • All-Digital Calibration
  • USB Port
  • Lightweight Yet Ruggedly Built
  • Simple 5-Button Interface

The Ludlum Model 3000 is a durable, lightweight instrument that is used with an external detector for alpha, beta, and gamma radiation survey. It features a large, easy-to-read LCD screen and audible alarms and is controlled using a simple five-button interface. The unit body is made of high-impact plastic, and splash-resistant construction allows the instrument to be used outdoors.

Three modes of operation are available – RATE, MAX, and COUNT – which can be selected by pressing the MODE button. Measurements can be collected in two sets of units (primary and secondary) for RATE and MAX modes in cps, cpm, Bq, dpm, mR/hr, or µSv/h units. The user can switch between two sets of chosen units by pressing the UNITS button. When enabled with the optional Lumic Data Logger Kit (see Options), data can be logged in any of the operational modes using the LOG button on the handle. Up to 1000 data points can be stored internally.

Instrument setup can be done either through the front-panel controls or via the Lumic Calibration Kit (see Options). The Model 3000 is shipped ready to use with batteries and calibration certificate.

 

  • Specifications
  • Options
  • Documents
  • Firmware Updates
  • Video
  • Specifications
  • Options
  • Documents
  • Firmware Updates
  • Video

Specifications

Compatible Detectors GM, scintillation, or proportional
Display 3 digit auto-ranging LCD with large 20 mm (0.8 in.) digits.
Units: (k)cps, (k)cpm, (k)Bq, (k)dpm, (µ)(m)R(/h), (µ)(m)Sv(/h).
Indicators: bar graph, MAX, ALARM, USB, audio, low battery.
Display Range
  • 0.0 cps to 99.9 kcps
  • 0.00 cpm to 999 kcpm
  • 0.00 Bq to 99.9 kBq
  • 0.00 dpm to 999 kdpm
  • 0.00 µR/h to 999 R/h
  • 0.00 µSv/h to 999 Sv/h
Operational display ranges are dependent on the detector and dead time configuration. The minimum and maximum display can be set to limit the display to the calibrated range.
Linearity Readings within 10% of true value
Backlight Built-in ambient light sensor automatically activates low-power LED backlight, unless internal dipswitch is set to continuous-On (will reduce battery life)
Controls
  • ON/OFF: Extra-long press to turn ON; Short press to acknowledge alarms; Extra-long press plus 3 seconds to turn OFF
  • UNITS: Short press changes the units between count rate, dose/exposure, or disintegration; Extra-long press to change count time in COUNT mode
  • AUDIO: Short press to adjust audio level
  • MODE: Short press alternates between available modes - RATE (displays count rate), MAX (captures peak rate), and COUNT (captures rate or dose readings for a user-selectable count time from 0 to 10 minutes)
  • LOG: Short press to log current display (requires Lumic Data Logger Kit), or initiate count in COUNT mode
Data Logging Can store up to 1000 data points internally. Requires Lumic Data Logger Kit, see Options.
Response Time User-selectable from 1 to 60 seconds, or auto-response rate FAST or SLOW
Alarms Two count rate, exposure/dose, and count alarm setpoints adjustable over the display range
Overload Protection High count rate saturation protection prevents false display of lower count rates. “OL” will appear on the display and an audio warning will be triggered.
Loss of Count Protection After a user-defined time of no pulses from detector, typically 60 seconds, the unit will flash a zero reading, and an audio alarm will be triggered.
Overrange If reading exceeds the predefined detector range, the instrument will flash a maximum reading and trigger an audio warning.
Dead Time Correction Employs first and second order corrections for extended performance
High Voltage 400 to 1500 Vdc
Threshold -4 to -100 mVdc
Audio Approximately 4.5 kHz; Click audio greater than 65 dB at 0.6 m (2 ft); Alarm audio greater than 72 dB
Power Four alkaline “AA” batteries
Battery Life Approximately 750 hours of operation (as low as 100 hours with backlight configured for continuous-on), 16-hour low battery warning
Construction High-impact plastic with water-resistant rubber seals and separate battery compartment
Temperature Range -20 to 50 °C (-5 to 122 °F)
May be certified for operation from -40 to 65 °C (-40 to 150 °F)
Environmental Rating NEMA rating of 5 or IP rating of 53
Size (H x W x L) 16.5 x 11.4 x 21.6 cm (6.5 x 4.5 x 8.5 in.)
Weight 0.7 kg (1.6 lb) (excluding detectors and clips)

Options

OptionDescriptionPart Number
Lumic Calibration Kit
Lumic Calibration Software allows the reading and writing of important parameters via a USB port in the Model 3000 Series and Model 30 family of instruments. This software also includes a calibration wizard (guides the user through calibration steps) and a plateau wizard (determines the optimal detector operating voltage).

The kit includes Lumic Calibration Software versions 1.0 and 2.0, a Model 3000 Series USB cable, and a Model 30 family USB cable.
4519-865
Lumic Configuration Kit
Lumic Configuration Software allows the reading and writing of important parameters via a USB port in the Model 3000 Series and Model 30 family of instruments. Does not include calibration or plateau wizards.

The kit includes the Lumic Configuration Software, a Model 3000 Series USB cable, and a Model 30 family USB cable.
4519-747
Lumic Data Logger Kit
(Model 3000-Series)
Includes Lumic Data Logger Software and cable. 4498-1019
worker_w_phone--instrument7
Model 3000 Series
Bluetooth® Option & Lumic Linker
Wirelessly connects the instrument with an Android or iOS mobile device. 4498-1024
RS232 serial optionRS-232 Serial Port Adds a true RS-232 serial port connector. 4519-490
TTL serial optionTTL Serial Port Adds a TTL 3.3 V serial port connector. Available modes are instrument dependent, contact us for more information on configuration options. 4519-155
Headphone Jack
Adds a headphone jack to the instrument. 4498-555
stereo_mono_headphones
Stereo/Mono Headphones
Adjustable stereo/mono headphones. 22-9313
M3000 Series with Strap
Shoulder Strap
1.8 m (6 ft) adjustable nylon shoulder strap. Requires instrument case modification. 4498-868
m2312958_open
Model 3000-Series Case
Rugged, dust- and waterproof transport and storage case. 2312958
m3002_frontfaceview
Model 3000-Series
Data Logging Handle
Retrofits legacy Model 3000-Series instruments supplied without the data logging handle with the required firmware and a replacement handle incorporating a data logging button. 4498-428

Documents

  • Data Sheet
  • Product Manual
  • CE Certificate
  • Model 3000 Series Comparison Table
  • Options for Model 3000 Series

Firmware Updates

In order to use the latest Lumic Calibration Software*, you may need to update the firmware on your instrument. (All new instruments will be compatible with the latest software version.) Use the table below to determine the firmware requirement for your instrument.

Software Version Compatible Models Required Firmware
Lumic 1.0 30, 30-4, 30-6, 30-7, 35, 79 2.x or lower
3000, 3001, 3005, 3006, 3019, 3276 N34 or lower
3002, 3277 N12 or lower
Lumic 2.0 30, 30-4, 30-6, 30-7, 35, 79 3.x or higher
3000, 3001, 3005, 3006, 3019, 3276 N40 or higher
3002 N20 or higher
3003, 3014, 3078 N/A

*Note: If you purchased the original Lumic 1.0 software, you are eligible for a free copy of Lumic 2.0. Please contact your local sales representative or Ludlum Measurements to receive your copy.


To update the firmware on your instrument:
  1. Download the appropriate instructions file (PDF) for your instrument.
    IMPORTANT: The firmware update instructions are model number specific. You must use the instructions for your specific instrument model. See table below.

    Model Instructions File
    30, 30-4, 30-6, 30-7, 35, 79 Lumic Firmware Update Instructions (Model 30/35/79 Series)
    3000, 3001, 3002, 3005, 3006, 3019, 3276 Lumic Firmware Update Instructions (Model 3000 Series, Gen 1)
    3003, 3014, 3078 Lumic Firmware Update Instructions (Model 3000 Series, Gen 2)
  2. Download the latest Lumic Firmware Updater Software.
  3. Determine the printed circuit board number your instrument has. To do this, you must open the instrument can and find the number on the circuit board.
  4. Using the drop-down selectors below, select your instrument model and printed circuit board number. This will populate a list of available firmware downloads for your instrument.

Video

Model 3000 Device Menu Overview


Related Products

m3003_web
Model 3003 Series
m3001_face_w_log-button--handle-1b
Model 3001
m3014
Model 3014
m14c-lftt-angle-trans500px
Model 14C
m3002_frontrtangleview_500
Model 3002
m3-lft-angle-w-handle-4-trans-merged_500px
Model 3
m3a-lft-angle-trans_500px
Model 3A
Results 1 - 7 of 7

Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.